ermcenter.com

Home > Event Id > Event Id 2335 Not A Certified Drive

Event Id 2335 Not A Certified Drive

Contents

We purchased a 600GB SAS Seagate Cheetah drive to be able to migrate some databases to, but when I installed it the drive never registered. If your server has significant IO load, lacking write-back will kill IO performance. Join & Ask a Question Need Help in Real-Time? Dell did this, and a lot of people made a fuss but it wasn't on the PERC6's it was the H series (and they released an update that changed this).  They have a peek here

Join the community Back I agree Powerful tools you need, all for free. And along similar lines, a tip I found the other day for anyone running software RAID... Server Administrator Version 8.3 Messages Reference Guide Visa innehållsförteckning Notes, cautions, and warningsIntroductionNew in this releaseAlert Message Change HistoryMessages Not Described in This GuideUnderstanding Event MessagesSample Event Message TextViewing Alerts and Check the health of the storage components. http://en.community.dell.com/support-forums/servers/f/906/t/18997241

Event Id 2335 Not A Certified Drive

If not, give it some time to charge. Take the event log quiz now! Event ID: 2057 Source: Server Administrator Category: Storage Service Message: Virtual disk degraded: Virtual Disk 1 (Virtual Disk 1) Controller 0 (PERC 5/i Integrated) You can rip out the controller and replace it directly with an identical make / model and still have the RAID configuration left intact. What exactly did Dell tell you to do? 0 Efficient way to get backups off site to Azure Promoted by Veeam Software This user guide provides instructions on how to deploy

we have a client that is still running a web site on a Compaq server from the late 90's and recently had to fix a machine with a dedicated Compaq MFM read more... And along similar lines, a tip I found the other day for anyone running software RAID... Dell Poweredge 2950 Raid Battery Replacement Thanks, 0 Comment Question by:itconsultant7717 Facebook Twitter LinkedIn https://www.experts-exchange.com/questions/25016462/PERC-6-i-Integrated-Controller-Battery-Warning.htmlcopy LVL 14 Best Solution bycharlestasse The message that you are seeing is normal, expecially if you see this message shortly after restarting

WT means write through. Perc 6/i Battery Replacement Useless battery check:# omreport storage battery controller=0Battery 0 on Controller PERC 5/i Integrated (Embedded)Controller PERC 5/i Integrated (Slot Embedded)ID                  : 0 Status              : OkName                : Battery 0State               : ReadyRecharge Count      : I'm looking at the event logs on another server and see the following error message: Source: Server Administrator Category: Storage Service Event ID: 2335 Description: Controller event log: Current capacity of https://www.experts-exchange.com/questions/25016462/PERC-6-i-Integrated-Controller-Battery-Warning.html K 0 LVL 1 Overall: Level 1 Storage 1 Server Hardware 1 Message Active 1 day ago Expert Comment by:InterWorks ID: 261749712010-01-04 That message is normal, especially after reboots.

x 13 Private comment: Subscribers only. Nu209 Battery myeventlog.com and eventsentry.com are part of the netikus.net network . All rights reserved. If you look in server administrator you will see that the battery is charging during this and a few mins latter the notification goes away.

Perc 6/i Battery Replacement

All rights reserved. http://www.myeventlog.com/search/show/708 If you want to save money, and support everything yourself buy a SuperMicro.... Event Id 2335 Not A Certified Drive Installation of components that are outside the control of Cisco in terms of specifications can have adverse affects on the performance of the equipment either immediately or over a period such Dell P/n 0nu209 Expand the Physical Array category and right-click the PERC to display the associated menu.

Considering most Cisco servers are less than 4 years old, I'm curious WHY you'd be doing this?  Want to play with some cheap MLC flash for a non-persistent View farm or navigate here The configuration file is out of date or corrupted. On reboot or bootup, the Perc controller always tops up the raid battery, the process Go to Solution +3 6 Participants Alan Hardisty LVL 76 Server Hardware7 Storage5 Disaster Recovery4 dlethe English: Request a translation of the event description in plain English. Battery On Controller Perc 6/i Integrated Learning

Sounds like a vendor lock-in more than anything... Add Cancel × Insert code Language Apache AppleScript Awk BASH Batchfile C C++ C# CSS ERB HTML Java JavaScript Lua ObjectiveC PHP Perl Text Powershell Python R Ruby Sass Scala SQL If it reappears time and time again, you should download OpenManage Server Administrator, go under System >Log, and clear the log. Check This Out Management Pack CatalogA10 Management Pack 1 Acer Smart Integration Pack 8 Active Directory 2008 Audit Management Pack 1 Adobe Flash Mediaserver Management Pack for SCOM 2007 1 Amalga UIS 2009 3

This text is from events in the controller event log that were generated while Storage Management was not running. Perc Battery Connect with top rated Experts 14 Experts available now in Live! It turns out every time there was this error message in the logs the server restarted.

This meant we had to completely rebuild the RAID configuration and restore data which was very time consuming.

Recommend Us Quick Tip Connect to EventID.Net directly from the Microsoft Event Viewer!Instructions Customer services Contact usSupportTerms of Use Help & FAQ Sales FAQEventID.Net FAQ Advertise with us Articles Managing logsRecommended The Raid batteries last for years and years, there is no reason to replace it unless it fails. Help Desk » Inventory » Monitor » Community » Home System Center CoreTechnical documentation Library of management packs for Operations Manager and Service Manager. Dell Warranty Check TheEventId.Net for Splunk Add-onassumes thatSplunkis collecting information from Windows servers and workstation via the Splunk Universal Forwarder.

Butik Support Community Mitt konto Butik Support Community ×Close Loading, Please wait. Email: Name / Alias: Hide Name Solution Your solution: * Additional Links Name: URL:

Copyright 2016 Netikus.net. SCSI sense data: Sense key: 3 Sense code: 11 Sense qualifier: 0: Physical Disk 1:0:4 Controller 0, Connector 1 More information Event ID: 2166 Source: Server Administrator Category: Storage Service Message: this contact form More information Event ID: 1552 Source: Server Administrator Message: Log size is no longer near or at capacity Log type: ESM More information Event ID: 2415 Source: Server Administrator Category: Storage

You may get a better answer to your question by starting a new discussion. Did you talk to Dell to explain why the RAID configuration was lost? As an example non-bootable Windows 2012R2 installation is used which has boot problems. On 13-01-25 02:19 PM, D G Teed wrote: Thought I'd share a server tip.

Debian does this in a first Sunday in the month cron .That command is essentially the meat of /usr/share/mdadm/checkarrayRedhat includes this resync in /etc/cron.weekly/99-raid-check _______________________________________________ nSLUG mailing list [hidden email] http://nslug.ns.ca/mailman/listinfo/nslug Join our community for more solutions or to ask questions. Kitts och Nevis St. Event ID: 2335 Source: Server Administrator Source: Server Administrator Type: Warning Description:Controller event log: Current capacity of the battery is below threshold:Controller 0 (PERC 5/i Integrated).

If it does, excellent. Regarding your other server errors, again, then same issue should not affect the RAID config, but then Dell would be best placed to answer this categorically. All rights reserved. Download guide LVL 26 Overall: Level 26 Server Hardware 23 Storage 9 Disaster Recovery 2 Message Expert Comment by:lnkevin ID: 261749292010-01-04 For Dell Perc controller, you should be able to

Cheers... Article by: Jane Finding original email is quite difficult due to their duplicates. All rights reserved. Then go under Storage >Perc6/i and make sure the battery shows fully charged.

Menu options, which may include Battery Reconditioning and Pause I/O, depend on the controller selected. Toggle navigation MyEventlog Home Browse Submit Event Log Resources Blog Quiz Event Search Event ID Source Category Message Are you an Event Log Guru? Related Alert Information Clear Alert Number: None Related Alert Number: None Local Response Agent (LRA) Number: 2060 SNMP Trap Numbers 753 Det finns inga tillgängliga data för ämnet Sverige Välj land