ermcenter.com

Home > Event Id > Event Id 7 The Device Tape Has A Bad Block

Event Id 7 The Device Tape Has A Bad Block

Also most of the time (maybe even all the time) when I cancel the job when it is waiting for the 2nd tape it does not cancel, it just sits with By joining you are opting in to receive e-mail. Once the autoloader or tape drive has fully initialized, power the server back on. UMI: V-79-57344-33035 Physical Volume Library Drive not found. http://ermcenter.com/event-id/event-id-7-the-device-device-harddisk0-dr0-has-a-bad-block.html

The request could not be performed because of an I/O error" is reported in Symantec Backup Exec for Windows Servers (BEWS) when attempting any tape media operation. jimsturtz Members Profile Send Private Message Find Members Posts Add to Buddy List Newbie Joined: 21 February 2010 Status: Offline Points: 2 Post Options Post Reply Quotejimsturtz Report Post Thanks(0) It is also possible that Symantec is in the process of qualifying the particular device for that connection method. And we will behappy to help you again. Continued

Backup Exec may not be able properly communicate with tape hardware if another vendor's backup application is installed, even if the services for that application are disabled. Contact your system administrator. 15 Comments for event id 7 from source Kerberos Source: Keyex Type: Error Description:Service failed to start. 1 Comment for event id 7 from source Keyex Source: Failed to initialize the WMI configuration. 2 Comments for event id 7 from source Live Communications User Services Source: ltmodem Type: Error Description:The description for event id (7) cannot be found.It To correct this error, update to the most recent Backup Exec tape device drivers, run a cleaning job, and replace the media with new media, if possible.

Expand out Software Environment and the click on System Drivers. This is an error occurring within the driver or hardware itself. RE: The device, \Device\Tape0, has a bad block. Hungster (IS/IT--Management) 2 Aug 02 12:17 Lancehave you updated the latest driver for the tape drive ?plus have you try to re-install the backup exec ?twice i had the same problem,

To correct this error, slow down the SCSI bus and install the most recent SCSI drivers and firmware.  Event ID 15: This error indicates that the device is not ready to When they programs encounter an error, they will fix it in one or two tries. CBradshaw (IS/IT--Management) (OP) 2 Aug 02 02:56 What do you mean check your tape drive....what am i checking it for...am i checking physically or through OS...Just a bit moer help required Event id 7 from source win32slService has no comments yet.

Posting Guidelines Promoting, selling, recruiting, coursework and thesis posting is forbidden.Tek-Tips Posting Policies Jobs Jobs from Indeed What: Where: jobs by HomeForumsServer RackBack-up SystemsSymantec: Backup Exec back-up Forum The device, \Device\Tape0, If these errors occur, contact the hardware manufacturer. Figure 2 b. Monday, January 06, 2014 4:54 PM Reply | Quote 0 Sign in to vote I've been a fan of Hiren's Boot CD.

Make sure to backup all files before reformatting. The inquiry string must match exactly between the HCL and what is being reported to the server by the device. a. Orphaned Devices in Windows Device Manager and/or devices no longer detected or offline in Backup Exec Please see the following document for how to check for orphaned devices in Windows Device

The adamm.log file is appended to each time the Backup Exec services are started, and the detailed information for each device is outputted to this log during a process called Device navigate here Status: ReaderCompletionUnknownMsgType 1 Comment for event id 7 from source WudfUsbccidDriver Subscribe Subscribe to EventID.Net now!Already a subscriber? Source: sfloppy Type: Error Description:The device, \Device\Floppy0, has a bad block. If the option is not selected, select the option and proceed with the installation.

Event ID: 7Type: ErrorSource: disk"The device, \Device\Harddisk0\D, has a bad block." (Most prevalent) Event ID: 11Type: ErrorSource: disk"The driver detected a controller error on \Device\Harddisk2\D." Event ID: 51Source: diskType: Warning"An error Not had a chance yet. The problem is: According to what I have discovered yet, the issue must be my third hard disk, second partition! Check This Out Verify that the inquiry string matches the Hardware Compatibility List (HCL) If the device is presenting itself properly to the operating system, then it should be supplying the operating system with

For further support contact the hardware vendor. Verify that the SCSIChanger service is started. Email Address (Optional) Your feedback has been submitted successfully!

No backup?

http://support.veritas.com/docs/318581 323364:Jobs goes to queued state and all tapes are marked as not appendable (media full) without writing data, even after running a quick erase on new tape media http://support.veritas.com/docs/323364 199542:Backups Entrada más reciente Entrada antigua Página principal Suscribirse a: Enviar comentarios (Atom) Docteca [email protected] Etiquetas AntiVirus (3) Backup Exec (3) BLOG (2) CLI (7) Commvault (3) Data Protector; HP (1) Data Verify that the Driver Provider is Symantec. Muscle Memory is correct but I bet roids have been also concerned when you said: his paycheck trusted it.Also visit my homepage: building muscle mass diet for womenResponderEliminarAnónimo15 de junio de

Error Code: 0xa00084f0 The device timed out UMI: V-79-65535-34032 The device timed out UMI: V-79-57344-34037 Error e00084f5: The block sized being used is bad. I have tried putting on a freezer for 15-30 minutes and see if I will able to have a chance to retrieve files/folders. Confirm that the tape drive is functioning properly:  Check with the tape drive manufacturer for diagnostic software to test the condition of the tape drive hardware.    10. this contact form He claims that they require to acquire an edge irrespective of what it takes, after which he talks about steroids.

Using the above example (Figure 5), this device is supported when connected via SCSI. Registration on or use of this site constitutes acceptance of our Privacy Policy. Source: WudfUsbccidDriver Type: Error Description:Device responded with an error status. Template subject name, signature, or hardware requirements cannot be met.

For additional troubleshooting information, please refer to the TechNotes in the Related Documents Section below. In order for the device to work properly within Backup Exec, the inquiry string the device provides must match exactly with what is documented on the HCL: http://entsupport.symantec.com/carveout_PID_15047_view_CL.htm The inquiry string Thanks in advance. After disabling the device, right-click the device again, this time choosing delete.

While in the Computer Management or the Server Management console, review the System Event Logs and see if there are any hardware errors being reported from the tape drive, robotic library, Note 1: Anytime Backup Exec goes from being to able to properly detect or communicate with externally connected tape hardware to not being able to manage it, the procedure above should This error usually occurs when the device is malfunctioning or is configured incorrectly. The database is corrupt.) shows afterward in the System Event Viewer Log, this error can usually be ignored and will stop occurring after one or more reboots of the server have

Verify that there are no orphaned tape drives, medium changers, or controllers. No valid certificate authority can be found to issue this template. 2 Comments for event id 7 from source AutoEnrollment Source: b57w2k Type: Information Description:Broadcom NetXtreme 57xx Gigabit Controller: Network controller http://support.veritas.com/docs/191694 231488:Reasons why the data throughput rate can be slower than the theoretical maximum when backing up to or restoring from tape media or disk (B2D) & how to troubleshoot or Verify the device configuration is supported by Backup Exec a.

In certain high end servers, moving the SCSI card to a different Peripheral Component Interconnect (PCI) slot, one that does not share the same bus as a RAID controller, has been This issue indicates SCSI bus timeouts.  Event ID 11. http://support.veritas.com/docs/199542 320867:LTO tape drive shows a yellow question mark on, is detected under other devices in the Windows Device Manager, and the Symantec tape device drivers cannot be loaded http://support.veritas.com/docs/320867 304178:BSOD